Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.447
Filtrar
1.
J Robot Surg ; 18(1): 150, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38564025

RESUMO

Pedicle screw placement (PSP) is the fundamental surgical technique that requires high accuracy for novice orthopedists studying spinal oncology education. Therefore, we set forth to establish a computer-assisted robotic navigation training program for novice spinal oncology education. Novice orthopedists were involved in this study to evaluate the feasibility and safety of the computer-assisted robotic navigation (CARN) training program. In this research, trainees were randomly taught by the CARN training program and the traditional training program. We prospectively collected the clinical data of patients with spinal tumors from 1st May 2021 to 1st March 2022. The ability of PSP was evaluated by cumulative sum (CUSUM) analysis, learning curve, and accuracy of pedicle screws. The patients included in both groups had similar baseline characteristics. In the CUSUM analysis of the learning curve for accurate PSP, the turning point in the CARN group was lower than that in the traditional group (70th vs. 92nd pedicle screw). The LC-CUSUM test indicated competency for PSP at the 121st pedicle screw in the CARN group and the 138th pedicle screw in the traditional group. The accuracy of PSP was also significantly higher in the CARN group than in the traditional group (88.17% and 79.55%, P = 0.03 < 0.05). Furthermore, no major complications occurred in either group. We first described CARN in spinal oncology education and indicated the CARN training program as a novel, efficient and safe training program for surgeons.


Assuntos
Parafusos Pediculares , Procedimentos Cirúrgicos Robóticos , Cirurgiões , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Curva de Aprendizado , Computadores
2.
Medicine (Baltimore) ; 103(16): e37885, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38640290

RESUMO

RATIONALE: Aggressive vertebral hemangiomas (AVHs) destroy continuous vertebral bodies and intervertebral discs and resulting in spinal kyphosis is extremely rare. The very aggressive behavior was attributable to its significant vascular component and contained no adipose tissue. PATIENT CONCERNS: We report a case of thoracic spine kyphosis of AVHs with multiple vertebral bodies and intervertebral disc destruction in a 45-year-old woman. DIAGNOSES: Based on the imaging studies, the patient underwent surgical removal of this lesion and spinal reconstruction. Histopathology consistent with vertebral hemangioma and contained no adipose. INTERVENTIONS: The patient underwent surgical removal of the lesion and spinal reconstruction. After subperiosteal dissection of the paraspinal muscles and exposure of the laminae, the laminae of the T5-7 vertebrae were removed and exposing the lesion. The lesion was soft and showed cystic changes, completely curetted and autogenous bone was implanted. Vertebroplasty was performed through T3-T9 pedicles bilaterally. Pedicle screw fixation was performed for segmental fixation and fusion. OUTCOMES: After 9 days of operation, the incision healed cleanly and free of pain. She was discharged in good general condition. The patient remained asymptomatic after follow-up 6 months of postoperative. LESSONS: AVHs destroy multiple vertebral bodies and intervertebral discs and resulting in spinal kyphosis is extremely rare.


Assuntos
Hemangioma , Cifose , Parafusos Pediculares , Fraturas da Coluna Vertebral , Feminino , Humanos , Pessoa de Meia-Idade , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Cifose/etiologia , Cifose/cirurgia , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/cirurgia , Vértebras Torácicas/lesões , Hemangioma/complicações , Hemangioma/cirurgia , Hemangioma/patologia , Resultado do Tratamento , Fraturas da Coluna Vertebral/cirurgia
3.
J Orthop Surg Res ; 19(1): 240, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622736

RESUMO

OBJECTIVE: To assess the radiographic outcomes, clinical outcomes and complications of percutaneous kyphoplasty (PKP) with and without posterior pedicle screw fixation (PPSF) in the treatment of severe osteoporotic vertebral compression fractures (sOVCF) with nonunion. METHODS: This study involved 51 patients with sOVCF with nonunion who underwent PKP or PPSF + KP. The operation time, intraoperative blood loss, volume of injected bone cement, operation costs and hospital stays were all recorded. In addition, the Visual Analogue Scale (VAS) and the Oswestry Disability Index (ODI) were assessed separately for each patient before and after surgery. RESULTS: Compared with the PPSF + KP group, the PKP group had shorter operation time, less intraoperative blood loss, shorter hospital stays and fewer operation costs. However, cobb's angle improvement (13.4 ± 4.3° vs. 21.4 ± 5.3°), VWR improvement ratio (30.4 ± 11.5% vs. 52.8 ± 12.7%), HA (34.9 ± 9.0% vs. 63.7 ± 7.6%) and HM (28.4 ± 11.2% vs. 49.6 ± 7.7%) improvement ratio were all higher in PPSF + KP group than that in PKP group. In addition, the ODI index and VAS score in both groups were significantly decreased at the postoperative and final follow-up. PKP group's postoperative VAS score was significantly lower than that in PPSF + KP group, but there was no statistically significant difference in VAS score at the last follow-up. CONCLUSION: PKP and PPSF + KP can both effectively relieve the pain associated with sOVCF with nonunion. PPSF + KP can achieve more satisfactory vertebral reduction effects compared to PKP. However, PKP was less invasive and it has more advantages in shortening operation time and hospital stay, as well as decreasing intraoperative blood loss and operation costs.


Assuntos
Fraturas por Compressão , Cifoplastia , Fraturas por Osteoporose , Parafusos Pediculares , Fraturas da Coluna Vertebral , Humanos , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/cirurgia , Fraturas por Compressão/tratamento farmacológico , Perda Sanguínea Cirúrgica , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Fraturas da Coluna Vertebral/tratamento farmacológico , Resultado do Tratamento , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/cirurgia , Fraturas por Osteoporose/tratamento farmacológico , Cimentos Ósseos/uso terapêutico , Estudos Retrospectivos
4.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 466-473, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632068

RESUMO

Objective: To investigate the effectiveness of injured vertebra fixation with inclined-long pedicle screws combined with interbody fusion for thoracolumbar fracture dislocation with disc injury. Methods: Between January 2017 and June 2022, 28 patients with thoracolumbar fracture dislocation with disc injury were underwent posterior depression, the injured vertebra fixation with inclined-long pedicle screws, and interbody fusion. There were 22 males and 6 females, with a mean age of 41.4 years (range, 22-58 years). The causes of injury included falling from height in 18 cases, traffic accident in 5 cases, and bruise in 5 cases. Fracture segment included 1 case of T 11, 7 cases of T 12, 9 cases of L 1, and 11 cases of L 2. According to the American Spinal Injury Association (ASIA) scale, the spinal injuries were graded as grade A in 4 cases, grade B in 2 cases, grade C in 11 cases, and grade D in 11 cases. Preoperative spinal canal encroachment ratio was 17.7%-75.3% (mean, 44.0%); the thoracolumbar injury classification and severity score (TLICS) ranged from 9 to 10 (mean, 9.9). Seventeen patients were associated with other injuries. The time from injury to operation ranged from 1 to 4 days (mean, 2.3 days). The perioperative indicators (operation time, intraoperative blood loss, and the occurrence of complications), clinical evaluation indicators [visual analogue scale (VAS) score and Oswestry Disability Index (ODI)], radiologic evaluation indicators [anterior vertebral height ratio (AVHR), kyphosis Cobb angle (KCA), intervertebral space height (ISH), vertebral wedge angle (VWA), displacement angle (DA), and percent fracture dislocation displacement (PFDD)], neurological function, and interbody fusion were recorded. Results: The operation time was 110-159 minutes (mean, 130.2 minutes). The intraoperative blood loss was 200-510 mL (mean, 354.3 mL). All incisions healed by first intention, and no surgical complications such as wound infection or hematoma occurred. All patients were followed up 12-15 months (mean, 12.7 months). The chest and lumbar pain significantly relieved, VAS scores and ODI after operation were significantly lower than those before operation, and further decreased with the extension of postoperative time, with significant differences ( P<0.05). At last follow-up, the ASIA classification of neurological function of the patients was grade A in 3 cases, grade B in 1 case, grade C in 1 case, grade D in 10 cases, and grade E in 13 cases, which was significantly different from preoperative one ( Z=-4.772, P<0.001). Imaging review showed that AVHR, KCA, ISH, VWA, DA, and PFDD significantly improved at 1 week, 3 months and last follow-up ( P<0.05). There was no significant difference between different time points after operation ( P>0.05). At last follow-up, according to the modified Brantigan score, all patients achieved good intervertebral bone fusion, including 22 complete fusion and 6 good intervertebral fusion with a few clear lines. No complications such as internal fixation failure or kyphosis occurred during follow-up. Conclusion: The injured vertebra fixation with inclined-long pedicle screws combined with interbody fusion is an effective treatment for thoracolumbar fracture dislocation with disc injury, which can correct the fracture dislocation, release the nerve compression, restore the injured vertebral height, and reconstruct spinal stabilization.


Assuntos
Fratura-Luxação , Fraturas Ósseas , Cifose , Parafusos Pediculares , Fraturas da Coluna Vertebral , Masculino , Feminino , Humanos , Adulto , Perda Sanguínea Cirúrgica , Vértebras Lombares/cirurgia , Fraturas da Coluna Vertebral/cirurgia , Vértebras Torácicas/cirurgia , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Estudos Retrospectivos
5.
Sci Rep ; 14(1): 9272, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653756

RESUMO

The transpedicular procedure has been widely used in spinal surgery. The determination of the best entry point is the key to perform a successful transpedicular procedure. Various techniques have been used to determine this point, but the results are variable. This study was carried out to determine the posterior endpoint of the lumbar pedicle central axis on the standard anterior-posterior (AP) fluoroscopic images. Computer-aided design technology was used to determine the pedicle central axis and the posterior endpoint of the pedicle central axis on the posterior aspect of the vertebra. The standard AP fluoroscopic image of the lumbar vertebral models by three-dimensional printing was achieved. The endpoint projection on the AP fluoroscopic image was determined in reference to the pedicle cortex projection by the measurements of the angle and distance on the established X-Y coordinate system of the radiologic image. The projection of posterior endpoint of the lumbar pedicle central axis were found to be superior to the X-axis of the established X-Y coordinate system and was located on the pedicle cortex projection on the standard AP fluoroscopic image of the vertebra. The projection point was distributed in different sectors in the coordinate system. It was located superior to the X-axis by 18° to 26° at L1, while they were located superior to the X-axis by 12° to 14° at L2 to L5. The projections of posterior endpoints of the lumbar pedicle central axis were located in different positions on the standard AP fluoroscopic image of the vertebra. The determination method of the projection point was helpful for selecting an entry point for a transpedicular procedure with a fluoroscopic technique.


Assuntos
Vértebras Lombares , Parafusos Pediculares , Vértebras Lombares/cirurgia , Vértebras Lombares/diagnóstico por imagem , Fluoroscopia/métodos , Humanos , Masculino , Feminino , Fusão Vertebral/métodos , Impressão Tridimensional , Desenho Assistido por Computador
6.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 55(2): 303-308, 2024 Mar 20.
Artigo em Chinês | MEDLINE | ID: mdl-38645868

RESUMO

Objective: To compare the clinical effects of cortical bone trajectory screws and traditional pedicle screws in posterior lumbar fusion. Methods: A retrospective study was conducted to analyze lumbar degeneration patients who underwent surgical treatment at our hospital between January 2016 and January 2019. A total of 123 patients who met the inclusion criteria were enrolled. The subjects were divided into two groups according to their surgical procedures and the members of the two groups were matched by age, sex, and the number of fusion segments. There were 63 patients in the traditional pedicle screws (PS) group and 60 in the cortical bone trajectory screws (CBTS) group. The outcomes of the two groups were compared. The primary outcome measures were perioperative conditions, including operation duration, estimated intraoperative blood loss (EBL), and length-of-stay (LOS), visual analog scale (VAS) score, Oswestry Disability Index (ODI) score, and interbody fusion rate. The secondary outcome measures were the time to postoperative ambulation and the incidence of complications. VAS scores and ODI scores were assessed before operation, 1 week, 1 month, 3 months, and 12 months after operation, and at the final follow-up. The interbody fusion rate was assessed in 1 year and 2 years after the operation and at the final follow-up. Results: The CBTS group showed a reduction in operation duration ([142.8±13.1] min vs. [174.7±15.4] min, P<0.001), LOS ([9.5±1.5] d vs. [12.0±2.0] d, P<0.001), and EBL ([194.2±38.3] mL vs. [377.5±33.1] mL, P<0.001) in comparison with the PS group. The VAS score for back pain in the CBTS group was lower than that in the PS group at 1 week and 1 month after operation and the ODI score in the CBTS group was lower than that in the PS group at 1 month after operation, with the differences being statistically significant (P<0.05). At each postoperative time point, the VAS score for leg pain and the interbody fusion rate did not show significant difference between the two groups. The VAS score for back and leg pain and the ODI score at each time point after operation in both the CBTS group and the PS group were significantly lower than those before operation (P<0.05). No significant difference was found in the time to postoperative ambulation or the overall complication incidence between the two groups. Conclusion: The CBTS technique could significantly shorten the operation duration and LOS, reduce EBL, and achieve the same effect as the PS technique does in terms of intervertebral fusion rate, pain relief, functional improvement, and complication incidence in patients undergoing posterior lumbar fusion.


Assuntos
Osso Cortical , Vértebras Lombares , Parafusos Pediculares , Fusão Vertebral , Humanos , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação , Vértebras Lombares/cirurgia , Estudos Retrospectivos , Masculino , Feminino , Osso Cortical/cirurgia , Duração da Cirurgia , Tempo de Internação , Pessoa de Meia-Idade , Resultado do Tratamento , Degeneração do Disco Intervertebral/cirurgia , Parafusos Ósseos , Perda Sanguínea Cirúrgica/estatística & dados numéricos
7.
Int J Med Robot ; 20(1): e2603, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38536722

RESUMO

BACKGROUND: To assess the accuracy of robot-assisted Magerl screw placement and explore the factors affecting the accuracy. METHODS: A retrospective analysis of patients who underwent robot-assisted Magerl screw placement was performed. The accuracy of Magerl screw placement was evaluated according to the Gertzbein and Robbins scale. RESULTS: 47 Magerl screws were placed in 24 consecutive patients. 32 Magerl screws were narrower than the C2 isthmus height and 26 of them were grade A. 15 Magerl screws were wider than the C2 isthmus height and all of them were grade B. Temporary fixation after decompression and a smaller difference between the C2 isthmus height and screw diameter were associated with a higher probability of cortical breach. CONCLUSION: The accuracy of robot-assisted Magerl screw placement was excellent. Temporary fixation after decompression and a smaller difference between the C2 isthmus height and screw diameter increased the risk of cortical breach.


Assuntos
Parafusos Pediculares , Procedimentos Cirúrgicos Robóticos , Robótica , Fusão Vertebral , Humanos , Estudos Retrospectivos , Parafusos Pediculares/efeitos adversos , Fatores de Risco
8.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(3): 331-336, 2024 Mar 15.
Artigo em Chinês | MEDLINE | ID: mdl-38500427

RESUMO

Objective: To evaluate the effectiveness of spinal canal decompression assisted by unilateral biportal endoscopy (UBE) and percutaneous uniplanar pedicle screw internal fixation in the treatment of lumbar burst fractures with neurological symptoms. Methods: Between June 2021 and December 2022, 10 patients with single level lumbar burst fracture with neurological symptoms were treated with spinal canal decompression assisted by UBE and percutaneous uniplanar pedicle screw internal fixation. There were 7 males and 3 females with an average age of 43.1 years (range, 21-57 years). The injured vertebrae located at L 1 in 2 cases, L 2 in 4 cases, L 3 in 3 cases, and L 4 in 1 case. There were 7 cases of AO type A3 fractures and 3 cases of AO type A4 fractures. The total operation time, the time of operation under endoscopy, and complications were recorded. Pre- and post-operative visual analogue scale (VAS) score and American Spinal Injury Association (ASIA) scale (grading A-E corresponding to assigning 1-5 points for statistical analysis) were used to evaluate effectiveness. X-ray film and CT were performed to observe the fracture healing, and the ratio of anterior vertebral body height, Cobb angle, and rate of spinal canal invasion were measured to evaluate the reduction of fracture. Results: All operations was successfully completed, and the spinal canal decompression and the bone fragment in spinal canal reduction completed under the endoscopy. Total operation time was 119 minutes on average (range, 95-150 minutes), and the time of operation under endoscopy was 46 minutes on average (range, 35-55 minutes). There was no complication such as dural sac, nerve root, or blood vessel injury during operation. All incisions healed by first intention. All patients were followed up 18.7 months on average (range, 10-28 months). The VAS score after operation significantly decreased when compared with that before operation ( P<0.05), and further improved at last follow-up ( P<0.05). The ASIA scale after operation significantly improved when compared with that before operation ( P<0.05), and there was no significant difference ( P>0.05) in the ASIA scale between at 1 week after operation and at last follow-up. The imaging examination showed that the screw position was good and the articular process joint was preserved. During follow-up, there was no loosening, fracture, or fixation failure of the internal fixation. The ratio of anterior vertebral body height and Cobb angle significantly improved, the rate of spinal canal invasion significantly decreased after operation ( P<0.05), and without significant loss of correction during the follow-up ( P>0.05). Conclusion: Spinal canal decompression assisted by UBE and percutaneous uniplanar pedicle screw fixation is a feasible minimally invasive treatment for lumbar burst fractures with neurological symptoms, which can effectively restore the vertebral body sequence, as well as relieve the compression of spinal canal, and improve the neurological function.


Assuntos
Fraturas Cominutivas , Fraturas por Compressão , Parafusos Pediculares , Fraturas da Coluna Vertebral , Masculino , Feminino , Humanos , Adulto , Vértebras Torácicas/cirurgia , Vértebras Lombares/cirurgia , Vértebras Lombares/lesões , Resultado do Tratamento , Fraturas da Coluna Vertebral/cirurgia , Fixação Interna de Fraturas/métodos , Endoscopia , Estudos Retrospectivos
9.
Acta Orthop Traumatol Turc ; 58(1): 20-26, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38525506

RESUMO

OBJECTIVE: It was aimed at evaluating the effect of the size of the pedicle screw placed on the fractured vertebra on the long-term radiological and clinical results of short-segment posterior instrumentation applied in the surgical treatment of thoracolumbar vertebral fractures. METHODS: This retrospective study included 36 patients who underwent short-segment posterior instrumentation surgery for a single-level thoracolumbar (T11-L2) fracture between January 2015 and March 2021. The patients included in the study were divided into 2 groups according to the size of the pedicle screw placed in the fractured vertebra (group A: intermediate screw 4.5 mm, ≤35 mm+less than 50% of the vertebral corpus length, m/f: 13/4, n: 17, age: 36.5; group B: intermediate screw 5.5 mm, ≥40 mm+more than 70% of the vertebral corpus length, m/f: 11/8, n: 19, age: 42.6). All patients were periodically evaluated clinically and radiologically. Vertebral compression angle (VCA), anterior and posterior vertebral body height (ABH-PBH), intraoperative parameters (instrumentation time and intraoperative fluoroscopy number), and complications were compared between the 2 groups. RESULTS: Both groups were comparable with respect to age, sex, level of injury, AO classification, mechanism of injury, and American Spinal Cord Injury Association impairment scale. Restoration of VCA and vertebral corpus heights was achieved sufficiently in both groups after operation (P < .0001). There was no significant difference between the 2 groups in terms of early postoperative VCA, VCA measured at final follow-up, or loss of correction in VCA. At the last follow-up, PBH was statistically significantly better preserved in group B (P=.0424). There was no difference between the 2 groups in terms of operation time and the number of intraoperative fluoroscopies. Implant failure was observed in 1 patient in group A. CONCLUSION: This study has revealed that using a long, thick pedicle screw placed in the fractured vertebra can better preserve the PBH at the final follow-up. No correlation was found between the size of the intermediate screw and the preservation of the correction in the postoperative vertebral heights and VCA during the follow-up. LEVEL OF EVIDENCE: Level III, Therapeutic Study.


Assuntos
Fraturas por Compressão , Parafusos Pediculares , Fraturas da Coluna Vertebral , Humanos , Adulto , Estudos Retrospectivos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Vértebras Lombares/lesões , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/cirurgia , Vértebras Torácicas/lesões , Fixação Interna de Fraturas/métodos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Resultado do Tratamento
10.
Acta Orthop Traumatol Turc ; 58(1): 57-61, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38525511

RESUMO

OBJECTIVE: This study aimed (1) to simulate pedicle screw pullout after intraoperative external wall perforation and (2) to assess restoration strength with different thread designs in the pedicle screw instrumentation for osteoporotic thoracic vertebrae. METHODS: Twenty fresh-frozen human cadaveric thoracic vertebra bodies were prepared and divided into 4 groups: group 1, 5.5 mm × 45 mm polyaxial single thread pedicle screws (PASTS); group 2, after wall injury 5.5 mm × 45 mm PASTS; group 3, 6.5 mm × 45 mm PASTS after wall injury; and group 4: 6.5 mm × 45 mm polyaxial mixed-threaded screws after wall injury. While group 1 was the control group, groups 2, 3, and 4 were used as study groups after the lateral wall breach. All prepared screw units were placed on a universal pullout measurement testing device. RESULTS: The mean bone mineral density for 20 thoracic vertebrae was 0.57 ± 0.12 g/cm2 (range 0.53-0.6 g/cm2 ). The mean pullout strength was 474.90 Newtons (N) for group 1, 412.85 N for group 2, 475.4 N for group 3, and 630.74N for group 4. The lateral wall breach caused a 14.1 % decrease in average pullout strength compared with the initial screw pullout. Mixed (double)-threaded screws increased pullout strength compared to 6.5 mm screws (P=.036) Conclusion: Using a 1 mm thicker polyaxial pedicle screw or mixed (double)-threaded pedicle screw seems to increase pullout strength; however, this was statistically significant only for group 4. In the thoracic spine, the redirection possibility of the pedicle screw is limited, and augmentation with cement will not be appropriate due to the risk of wall injury-related leakage. Therefore, care should be taken to avoid violating the lateral cortex by using appropriate pedicle entry points and trajectories.


Assuntos
Parafusos Pediculares , Vértebras Torácicas , Humanos , Vértebras Torácicas/cirurgia , Fenômenos Biomecânicos , Densidade Óssea , Cadáver , Vértebras Lombares/cirurgia , Teste de Materiais
11.
J Robot Surg ; 18(1): 138, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38554242

RESUMO

Robot-assisted pedicle screw placement is prone to guide wire migration, and the related influencing factors have not yet been discussed. Therefore, this study aimed to investigate and analyze the causes of robot-assisted spinal pedicle guide wire displacement and summarize the relevant treatment strategies. The surgical outcomes of 82 patients who underwent robotic-assisted pedicle screw spinal placement at our hospital between July 2022 and June 2023 were retrospectively analyzed. A total of 342 screws were placed in 82 patients; 47 guide wires were offset, 47 guide wires were replaced, and 295 guide wires were not significantly offset, with a first guide wire offset rate of 13.7% and a total guide wire offset rate of 12.1%. Univariate analysis showed that Screw placement level, whether respiration was controlled during guide wire placement, Hu value of CT, the position of needle insertion point, and operation time had a significant effect on guide wire deviation (P < 0.05). Multivariate logistic regression analysis showed that the inclusion of screw placement segments, whether breathing was controlled during guide wire placement, and Hu value of CT had a significant effect on guide wire offset (P < 0.05). Whether the guide wire was offset had no significant effect on the accuracy of subsequent pedicle screw implantation (P > 0.05). The level of screw placement, whether breathing was controlled during guide wire placement, and Hu value of CT were independent risk factors for guide wire deviation. When causing an excursion, screw orientation can be adjusted during intraoperative screw placement, and guide wire excursion has no significant impact on the accuracy of subsequent pedicle screw placement.


Assuntos
Parafusos Pediculares , Procedimentos Cirúrgicos Robóticos , Robótica , Fusão Vertebral , Cirurgia Assistida por Computador , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Retrospectivos , Vértebras Lombares/cirurgia
12.
Medicina (Kaunas) ; 60(3)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38541104

RESUMO

Lumbar interbody fusion procedures have seen a significant evolution over the years, with various approaches being developed to address spinal pathologies and instability, including posterior lumbar interbody fusion (PLIF), transforaminal lumbar interbody fusion (TLIF), anterior lumbar interbody fusion (ALIF), and lateral lumbar interbody fusion (LLIF). LLIF, a pivotal technique in the field, initially emerged as extreme/direct lateral interbody fusion (XLIF/DLIF) before the development of oblique lumbar interbody fusion (OLIF). To ensure comprehensive circumferential stability, LLIF procedures are often combined with posterior stabilization (PS) using pedicle screws. However, achieving this required repositioning of the patient during the surgical procedure. The advent of single-position surgery (SPS) has revolutionized the procedure by eliminating the need for patient repositioning. With SPS, LLIF along with PS can be performed either in the lateral or prone position, resulting in significantly reduced operative time. Ongoing research endeavors are dedicated to further enhancing LLIF procedures making them even safer and easier. Notably, the integration of robotic technology into SPS has emerged as a game-changer, simplifying surgical processes and positioning itself as a vital asset for the future of spinal fusion surgery. This literature review aims to provide a succinct summary of the evolutionary trajectory of lumbar interbody fusion techniques, with a specific emphasis on its recent advancements.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Humanos , Vértebras Lombares/cirurgia , Fusão Vertebral/métodos , Região Lombossacral , Estudos Retrospectivos
13.
Med Eng Phys ; 125: 104137, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38508790

RESUMO

Osteoporosis is a common bone disease that often leads to difficulty in vertebrae revision. Traditional pedicle screws are often complicated to operate and have poor visibility during implantation. A new detachable pedicle screw is needed to improve the revision effect. The aim of this study was to design a new detachable pedicle screw based on medical optical imaging to improve the outcome of vertebral revision in osteoporosis, and to improve operational feasibility and visibility. In this study, the parameters related to the degree of osteoporosis were obtained by optical imaging detection of the osteoporotic vertebral body. Then a new detachable pedicle screw was designed according to the test results to improve the effect of vertebral body revision. By preparing and optimizing the material and structure of the screw, it is ensured that it has sufficient mechanical strength and stability. Finally, the visibility and operability of the improved screw during implantation were verified by medical optical imaging. Compared with traditional screws, the new detachable pedicle screw can improve the vertebral body revision in the case of osteoporosis. The optical imaging test results show that the new screw has good visibility and maneuverability, providing more accurate guidance and positioning for the vertebral body revision operation.


Assuntos
Osteoporose , Parafusos Pediculares , Humanos , Corpo Vertebral , Cimentos Ósseos , Fenômenos Biomecânicos , Osteoporose/diagnóstico por imagem , Osteoporose/cirurgia , Vértebras Lombares/cirurgia
15.
Proc Inst Mech Eng H ; 238(4): 455-460, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38480483

RESUMO

Synthetic bone models such as polyurethane (PU) foam are a well-established substitute to cadaveric bone for screw pull-out testing; however, little attention has been given to the effect of PU foam anisotropy on orthopaedic implant testing. Compressive and screw pull-out performance in three PU foam densities; 0.16 g/cm3 (PCF 10), 0.32 g/cm3 (PCF 20) and 0.64 g/cm3 (PCF 40) were performed in each of the X, Y or Z orientations. The maximum compressive force, stiffness in the linear region, maximum stress and modulus were determined for all compression tests. Pedicle screws were inserted and pulled out axially to determine maximum pull-out force, energy to failure and stiffness. One-way ANOVA and post hoc tests were used to compare outcome variables between PU foam densities and orientations, respectively. Compression tests demonstrated the maximum force was significantly different between all orientations for PCF 20 (X, Y and Z) while stiffness and maximum stress were different between X versus Y and X versus Z. Maximum pull-out force was significantly different between all orientations for PCF 10 foam. No significant differences were noted for other foam densities. There is potential for screw pull-out testing results to be significantly affected by orientation in lower density PU foams. It is recommended that a single, known orientation of the PU foam block be used for experimental testing.


Assuntos
Parafusos Pediculares , Humanos , Poliuretanos , Teste de Materiais , Fenômenos Mecânicos , Fenômenos Biomecânicos
16.
Neuroradiology ; 66(5): 855-863, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38453715

RESUMO

PURPOSE: To assess the feasibility and technical accuracy of performing pedicular screw placement combined with vertebroplasty in the radiological setting. METHODS: Patients who underwent combined vertebroplasty and pedicle screw insertion under combined computed tomography and fluoroscopic guidance in 4 interventional radiology centers from 2018 to 2023 were retrospectively assessed. Patient demographics, vertebral lesion type, and procedural data were analyzed. Strict intra-pedicular screw positioning was considered as technical success. Pain score was assessed according to the Visual Analogue Scale before the procedure and in the 1-month follow-up consultation. RESULTS: Fifty-seven patients (38 men and 19 women) with a mean age of 72.8 (SD = 11.4) years underwent a vertebroplasty associated with pedicular screw insertion for the treatment of traumatic fractures (29 patients) and neoplastic disease (28 patients). Screw placement accuracy assessed by post-procedure CT scan was 95.7% (89/93 inserted screws). A total of 93 pedicle screw placements (36 bi-pedicular and 21 unipedicular) in 32 lumbar, 22 thoracic, and 3 cervical levels were analyzed. Mean reported procedure time was 48.8 (SD = 14.7) min and average injected cement volume was 4.4 (SD = 0.9) mL. A mean VAS score decrease of 5 points was observed at 1-month follow-up (7.7, SD = 1.3 versus 2.7, SD = 1.7), p < .001. CONCLUSION: Combining a vertebroplasty and pedicle screw insertion is technically viable in the radiological setting, with a high screw positioning accuracy of 95.7%.


Assuntos
Parafusos Pediculares , Fraturas da Coluna Vertebral , Vertebroplastia , Masculino , Humanos , Feminino , Idoso , Estudos Retrospectivos , Estudos de Viabilidade , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Vértebras Lombares/cirurgia , Vertebroplastia/métodos
17.
Medicine (Baltimore) ; 103(11): e34646, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38489680

RESUMO

The study aimed to determine the optimal entry points and trajectories for posterior subaxial cervical pedicle screw (CPS) fixation. Computed tomography (CT) and Mimics software were used to evaluate the subaxial cervical pedicle in 42 cervical spine CT scans. The width of the cervical pedicle was measured and compared at medial angulations of 30°, 35°, 40°, 45°, 50°, 55°, and 60° relative to the midline sagittal plane. Based on an observational examination of the positions of all cervical 3-dimensional models and screws, the proposed entry point for C3-7 CPS was analyzed. Although the variations in C3-6 pedicle width (PW) among 45°, 50°, and 55° were not statistically significant, they were significantly larger than the differences among 30°, 35°, 40°, and 60° angles (P < .05). The differences in C7 PW between the 30°, 35°, 40°, and 45° angles were not statistically different even though the 30°, 35°, 40°, and 45° angles were significantly bigger. (P < .05). The proposed entry point for C3-7 CPS was below the junction of the lateral and lower borders of the superior articular process joint surface. The entry point for C3-7 levels was below the junction of the lateral and lower borders of the superior articular process joint surface. The optimal medial angulation for the posterior C3-6 CPS was 45°-55° and that for the posterior C7 CPS was 30°-45°. The sagittal angle of the posterior C3-7 CPS was parallel to the corresponding upper endplate.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Humanos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Tomografia Computadorizada por Raios X/métodos , Pescoço , Fusão Vertebral/métodos
18.
J Orthop Surg Res ; 19(1): 185, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38491520

RESUMO

INTRODUCTION: When needed operative treatment of sacral fractures is mostly performed with percutaneous iliosacral screw fixation. The advantage of navigation in insertion of pedicle screws already could be shown by former investigations. The aim of this investigation was now to analyze which influence iliosacral screw placement guided by navigation has on duration of surgery, radiation exposure and accuracy of screw placement compared to the technique guided by fluoroscopy. METHODS: 68 Consecutive patients with sacral fractures who have been treated by iliosacral screws were inclouded. Overall, 85 screws have been implanted in these patients. Beside of demographic data the duration of surgery, duration of radiation, dose of radiation and accuracy of screw placement were analyzed. RESULTS: When iliosacral screw placement was guided by navigation instead of fluoroscopy the dose of radiation per inserted screw (155.0 cGy*cm2 vs. 469.4 cGy*cm2 p < 0.0001) as well as the duration of radiation use (84.8 s vs. 147.5 s p < 0.0001) were significantly lower. The use of navigation lead to a significant reduction of duration of surgery (39.0 min vs. 60.1 min p < 0.01). The placement of the screws showed a significantly higher accuracy when performed by navigation (0 misplaced screws vs 6 misplaced screws-p < 0.0001). CONCLUSION: Based on these results minimal invasive iliosacral screw placement guided by navigation seems to be a safe procedure, which leads to a reduced exposure to radiation for the patient and the surgeon, a reduced duration of surgery as well as a higher accuracy of screw placement.


Assuntos
Fraturas Ósseas , Parafusos Pediculares , Fraturas da Coluna Vertebral , Cirurgia Assistida por Computador , Humanos , Ílio/diagnóstico por imagem , Ílio/cirurgia , Ílio/lesões , Sacro/diagnóstico por imagem , Sacro/cirurgia , Sacro/lesões , Cirurgia Assistida por Computador/métodos , Fixação Interna de Fraturas/métodos , Fluoroscopia/métodos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia
19.
J Robot Surg ; 18(1): 121, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38492043

RESUMO

The efficacy and safety of robotic-assisted pedicle screw placement compared to traditional fluoroscopy-guided techniques are of great interest in the field of spinal surgery. This systematic review and meta-analysis aimed to compare the outcomes of these two methods in patients with spinal diseases. Following the PRISMA guidelines, we conducted a systematic search across PubMed, Embase, Web of Science, and Cochrane Library. We included randomized controlled trials comparing robotic-assisted and fluoroscopy-guided pedicle screw placement in patients with spinal diseases. Outcome measures included the accuracy of pedicle screw placement, postoperative complication rates, intraoperative radiation exposure time, and duration of surgery. Data were analyzed using Stata software. Our analysis included 12 studies. It revealed significantly higher accuracy in pedicle screw placement with robotic assistance (odds ratio [OR] = 2.83, 95% confidence interval [CI] = 2.20-3.64, P < 0.01). Postoperative complication rates, intraoperative radiation exposure time, and duration of surgery were similar between the two techniques (OR = 0.72, 95% CI = 0.31 to 1.68, P = 0.56 for complication rates; weighted mean difference [WMD] = - 0.13, 95% CI = - 0.93 to 0.68, P = 0.86 for radiation exposure time; WMD = 0.30, 95% CI = - 0.06 to 0.66, P = 0.06 for duration of surgery). Robotic-assisted pedicle screw placement offers superior placement accuracy compared to fluoroscopy-guided techniques. Postoperative complication rates, intraoperative radiation exposure time, and duration of surgery were comparable for both methods. Future studies should explore the potential for fewer complications with the robotic-assisted approach as suggested by the lower point estimate.


Assuntos
Parafusos Pediculares , Procedimentos Cirúrgicos Robóticos , Doenças da Coluna Vertebral , Fusão Vertebral , Cirurgia Assistida por Computador , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Parafusos Pediculares/efeitos adversos , Fusão Vertebral/métodos , Doenças da Coluna Vertebral/etiologia , Fluoroscopia/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Cirurgia Assistida por Computador/métodos , Vértebras Lombares/cirurgia
20.
Comput Methods Programs Biomed ; 247: 108096, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38447314

RESUMO

BACKGROUND AND OBJECTIVE: As part of spinal fusion surgery, shaping the rod implant to align with the anatomy is a tedious, error-prone, and time-consuming manual process. Inadequately contoured rod implants introduce stress on the screw-bone interface of the pedicle screws, potentially leading to screw loosening or even pull-out. METHODS: We propose the first fully automated solution to the rod bending problem by leveraging the advantages of augmented reality and robotics. Augmented reality not only enables the surgeons to intraoperatively digitize the screw positions but also provides a human-computer interface to the wirelessly integrated custom-built rod bending machine. Furthermore, we introduce custom-built test rigs to quantify per screw absolute tensile/compressive residual forces on the screw-bone interface. Besides residual forces, we have evaluated the required bending times and reducer engagements, and compared our method to the freehand gold standard. RESULTS: We achieved a significant reduction of the average absolute residual forces from for the freehand gold standard to (p=0.0015) using the bending machine. Moreover, our bending machine reduced the average time to instrumentation per screw from to . Reducer engagements per rod were significantly decreased from an average of 1.00±1.14 to 0.11±0.32 (p=0.0037). CONCLUSION: The combination of augmented reality and robotics has the potential to improve surgical outcomes while minimizing the dependency on individual surgeon skill and dexterity.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Humanos , Teste de Materiais , Vértebras Lombares/cirurgia , Fenômenos Biomecânicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...